HjartavöðvafrumugreinirACEA
xCELLigence RTCA Cardio
Hjartavöðvafrumugreinir
ACEA
xCELLigence RTCA Cardio
EXW Föst verð aukaskattur bætist við
5.000 EUR
Ástand
Notað
(fullkomlega virkur)
Staðsetning
Töltéstava 

Grunnupplýsingar
- Heiti vélar:
- Hjartavöðvafrumugreinir
- Framleiðandi:
- ACEA
- Gerð:
- xCELLigence RTCA Cardio
- Ástand:
- almennt endurnýjaður (notaður)
- Virkni:
- fullkomlega virkur
Verð og staðsetning
EXW Föst verð aukaskattur bætist við
5.000 EUR
- Staðsetning:
- 0184/3. Hrsz, 9086 Töltéstava, Magyarország

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A20172940
- Uppfærsla:
- síðast þann 03.10.2025
Lýsing
ACEA xCELLigence RTCA Cardio
Parameter Value / Description
Iedpfx Aoxiyfpehqebc
Application / use Real-time monitoring of cardiomyocyte contractility and viability; cardiotoxicity assessment
Well format 96-well (E-Plate Cardio 96)
Sampling / temporal resolution Entire 96-well plate read in ≤ 12.9 ms (i.e. ~12.9 ms per full-plate sweep)
Impedance measurement accuracy / Accuracy: ±1.5 % (at 1 Ω) (plus some offset)
repeatability Repeatability: 0.8 %
Impedance dynamic range 20 Ω to 2 kΩ
Output test signal 22 mV rms ±20%, with a maximum 5 mV DC offset at 10 kHz (also stated for 10, 25, 50 kHz)
Communication interface USB 2.0 (from analyzer to control unit)
Power / electrical input (analyzer) 100–250 VAC, 50/60 Hz, 25 W max
Physical dimensions / weight (analyzer) ~ 40.0 × 40.0 × 9.2 cm (W × D × H)
weight:
Parameter Value / Description
Iedpfx Aoxiyfpehqebc
Application / use Real-time monitoring of cardiomyocyte contractility and viability; cardiotoxicity assessment
Well format 96-well (E-Plate Cardio 96)
Sampling / temporal resolution Entire 96-well plate read in ≤ 12.9 ms (i.e. ~12.9 ms per full-plate sweep)
Impedance measurement accuracy / Accuracy: ±1.5 % (at 1 Ω) (plus some offset)
repeatability Repeatability: 0.8 %
Impedance dynamic range 20 Ω to 2 kΩ
Output test signal 22 mV rms ±20%, with a maximum 5 mV DC offset at 10 kHz (also stated for 10, 25, 50 kHz)
Communication interface USB 2.0 (from analyzer to control unit)
Power / electrical input (analyzer) 100–250 VAC, 50/60 Hz, 25 W max
Physical dimensions / weight (analyzer) ~ 40.0 × 40.0 × 9.2 cm (W × D × H)
weight:
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2020
265 Auglýsingar á netinu
Senda fyrirspurn
Sími & Fax
+36 62 99... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
Fullgengt
Skilaboðin þín hafa verið send.
Lítil auglýsing
Győr
2.899 km
Smásjá
LeicaLeitz DMRB 301-371.010
LeicaLeitz DMRB 301-371.010
Fullgengt
Skilaboðin þín hafa verið send.
Lítil auglýsing
Győr
2.899 km
Smásjá
OlympusIX70-S8F
OlympusIX70-S8F
Fullgengt
Skilaboðin þín hafa verið send.
Lítil auglýsing
Contamine-sur-Arve
2.598 km
Smásjá
WILDM3Z
WILDM3Z
Fullgengt
Skilaboðin þín hafa verið send.
Lítil auglýsing
Duxford
1.800 km
MORTI smásjá
MORTI
MORTI
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp



















































