Litrófsmælir ónotaður í upprunalegum umbúðumAgilent Technologies
Cary Eclipse G9800A
Litrófsmælir ónotaður í upprunalegum umbúðum
Agilent Technologies
Cary Eclipse G9800A
föst verð aukaskattur bætist við
10.500 EUR
framleiðsluár
2022
Ástand
Notað
Staðsetning
Borken 

Myndir sýna
Sýna kort
Upplýsingar um vélina
- Heiti vélar:
- Litrófsmælir ónotaður í upprunalegum umbúðum
- framleiðandi:
- Agilent Technologies
- Gerð:
- Cary Eclipse G9800A
- framleiðsluár:
- 2022
- Ástand:
- næstum eins og nýtt (notað)
Verð og staðsetning
föst verð aukaskattur bætist við
10.500 EUR
- Staðsetning:
- Einsteinstraße 8a, 46325 Borken, DE
Hringdu
Vélasala

Hefur þú þegar auglýst notaða vélina þína?
Seldu í gegnum Machineseeker án þóknunar.
Meira um sölu á vélum
Meira um sölu á vélum
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A19292481
- Tilvísunarnúmer:
- 24642
- uppfærsla:
- síðast þann 04.06.2025
Lýsing
Agilent
Model: G9800A
For sale is an Agilent Cary Eclipse Fluorescence Spectrophotometer
– unused in original packaging (without software).
As far as is known, the item was never used and is in like-new condition.
The original packaging is available and may show slight storage marks.
Year of manufacture: 11/2022
Agilent Technologies Cary Eclipse Fluorescence Spectrophotometer
Description:
The Cary Eclipse G9800A is a high-quality fluorescence spectrophotometer
for research, laboratory, and industrial use.
It offers exceptional sensitivity, speed, and ease of use
and is ideally suited for applications in the fields of biochemistry,
Dedpfx Acewp Embozoku
pharmacy, environmental analysis, and materials research.
Technical data:
Light source: Xenon flash lamp
Wavelength range: 200–900 nm
Measurement modes:
Emission and excitation spectra
Time-resolved fluorescence
Phosphorescence
Excitation-emission matrix (3D scan)
Software: Cary Eclipse Software (not included)
Detector: Highly sensitive photomultiplier (PMT)
Scan speed: Very fast (up to 80 nm/s)
Typical applications:
Analysis of proteins, DNA, enzymes
Detection of environmental contaminants such as PAHs
Fluorescent dyes & markers
Development of pharmaceutical agents
Manufacturer: Agilent Technologies (formerly Varian)
Model: G9800A – Cary Eclipse Fluorescence Spectrophotometer
Includes: Device, power cable, manual
Power supply / connection data:
Power connection:
IEC C14 socket (classic cold appliance plug, as used in PCs)
→ Connection via standard cold appliance cable
Mains voltage:
100–240 V AC, 50/60 Hz (automatic switching)
Power consumption:
Approx. 150–200 W (depending on operating mode)
Fuse:
Internally installed, typically T2A or T3.15A
Weight: approx. 28–32 kg
Scope of delivery: (See picture)
(Changes and errors in the technical data reserved!)
For further questions, we are happy to answer by phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Model: G9800A
For sale is an Agilent Cary Eclipse Fluorescence Spectrophotometer
– unused in original packaging (without software).
As far as is known, the item was never used and is in like-new condition.
The original packaging is available and may show slight storage marks.
Year of manufacture: 11/2022
Agilent Technologies Cary Eclipse Fluorescence Spectrophotometer
Description:
The Cary Eclipse G9800A is a high-quality fluorescence spectrophotometer
for research, laboratory, and industrial use.
It offers exceptional sensitivity, speed, and ease of use
and is ideally suited for applications in the fields of biochemistry,
Dedpfx Acewp Embozoku
pharmacy, environmental analysis, and materials research.
Technical data:
Light source: Xenon flash lamp
Wavelength range: 200–900 nm
Measurement modes:
Emission and excitation spectra
Time-resolved fluorescence
Phosphorescence
Excitation-emission matrix (3D scan)
Software: Cary Eclipse Software (not included)
Detector: Highly sensitive photomultiplier (PMT)
Scan speed: Very fast (up to 80 nm/s)
Typical applications:
Analysis of proteins, DNA, enzymes
Detection of environmental contaminants such as PAHs
Fluorescent dyes & markers
Development of pharmaceutical agents
Manufacturer: Agilent Technologies (formerly Varian)
Model: G9800A – Cary Eclipse Fluorescence Spectrophotometer
Includes: Device, power cable, manual
Power supply / connection data:
Power connection:
IEC C14 socket (classic cold appliance plug, as used in PCs)
→ Connection via standard cold appliance cable
Mains voltage:
100–240 V AC, 50/60 Hz (automatic switching)
Power consumption:
Approx. 150–200 W (depending on operating mode)
Fuse:
Internally installed, typically T2A or T3.15A
Weight: approx. 28–32 kg
Scope of delivery: (See picture)
(Changes and errors in the technical data reserved!)
For further questions, we are happy to answer by phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp