6 hringa hitastýristækiAutotherm
AWF 130-27/VK/6K
6 hringa hitastýristæki
Autotherm
AWF 130-27/VK/6K
föst verð aukaskattur bætist við
80.000 EUR
Ástand
Notað
Staðsetning
Borken 

Upplýsingar um vélina
- Heiti vélar:
- 6 hringa hitastýristæki
- Framleiðandi:
- Autotherm
- Gerð:
- AWF 130-27/VK/6K
- Ástand:
- mjög gott (notað)
Verð og staðsetning
föst verð aukaskattur bætist við
80.000 EUR
- Staðsetning:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A22147572
- Tilvísunarnúmer:
- 23415
- Uppfærsla:
- síðast þann 18.06.2026
Lýsing
Autotherm
Here we offer a 6-circuit temperature control unit.
Without an active refrigeration unit!
According to the enclosed technical brief:
Temperature range: -40°C … +85°C (extended temperature range -40°C…+130°C)
Increased heating capacity: 27 kW instead of 18 kW
Includes 1 temperature control in the main circuit
Includes 6 temperature measurements in the respective supply line
Includes 6 temperature measurements in the respective return line
Includes 6 flow rate and pressure measurements in the respective supply line
Includes 6 flow rate and pressure controls
1 l/min .. 12 l/min and 0.1 bar … 3 bar
Includes changeover control
Includes frequency inverter-controlled pump in the main circuit
Includes 6x 3-way valve
Includes 6 additional overflow valves, adjustable from 2 … 12 bar
Pre-set to 2.4 bar
Includes filling and emptying device
For all circuits, common/simultaneous operation
Includes 50l integrated tank
Includes pneumatic emptying function
Includes S7 control system
Energy saving and increased cooling capacity:
An additional glycol circuit integrated in the temperature control circuit takes over
the cooling of the consumer in a temperature range of +85°C
Djdpfxjzd Rtys Acgskp
to +30°C. The absorbed energy is transferred to the on-site
< 20°C cold water network. The cooling capacity is 50 kW at a
supply temperature of +20°C.
This increases the cooling rate in this temperature range and saves
energy due to the shorter running time of the refrigerant compressor.
(The dimensions of the basic unit, according to the data sheet, are increased by approx. 0.3 m²)
Assembly in a Rittal modular enclosure:
2x TS8 800x1000x2000 mm
1x additional, enclosed enclosure, min. 600x600x2000 mm
(for control/electrical components)
Supplied via on-site or optional cooling medium supply
Supply temperature, on-site cooling brine -43°C, cooling brine requirement 7.5 m³/h, continuously controlled
For cooling capacity, a cooling medium must be connected!
Weight approx. 1200 kg
Type: Autotherm temperature control unit AWF 130-27/VK/6K
Sale from our location!
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Here we offer a 6-circuit temperature control unit.
Without an active refrigeration unit!
According to the enclosed technical brief:
Temperature range: -40°C … +85°C (extended temperature range -40°C…+130°C)
Increased heating capacity: 27 kW instead of 18 kW
Includes 1 temperature control in the main circuit
Includes 6 temperature measurements in the respective supply line
Includes 6 temperature measurements in the respective return line
Includes 6 flow rate and pressure measurements in the respective supply line
Includes 6 flow rate and pressure controls
1 l/min .. 12 l/min and 0.1 bar … 3 bar
Includes changeover control
Includes frequency inverter-controlled pump in the main circuit
Includes 6x 3-way valve
Includes 6 additional overflow valves, adjustable from 2 … 12 bar
Pre-set to 2.4 bar
Includes filling and emptying device
For all circuits, common/simultaneous operation
Includes 50l integrated tank
Includes pneumatic emptying function
Includes S7 control system
Energy saving and increased cooling capacity:
An additional glycol circuit integrated in the temperature control circuit takes over
the cooling of the consumer in a temperature range of +85°C
Djdpfxjzd Rtys Acgskp
to +30°C. The absorbed energy is transferred to the on-site
< 20°C cold water network. The cooling capacity is 50 kW at a
supply temperature of +20°C.
This increases the cooling rate in this temperature range and saves
energy due to the shorter running time of the refrigerant compressor.
(The dimensions of the basic unit, according to the data sheet, are increased by approx. 0.3 m²)
Assembly in a Rittal modular enclosure:
2x TS8 800x1000x2000 mm
1x additional, enclosed enclosure, min. 600x600x2000 mm
(for control/electrical components)
Supplied via on-site or optional cooling medium supply
Supply temperature, on-site cooling brine -43°C, cooling brine requirement 7.5 m³/h, continuously controlled
For cooling capacity, a cooling medium must be connected!
Weight approx. 1200 kg
Type: Autotherm temperature control unit AWF 130-27/VK/6K
Sale from our location!
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp