Háspennumælis vakutengill
Chilworth JCI 164

VB aukaskattur bætist við
1.600 EUR
Ástand
Notað
Staðsetning
Borken Þýskaland
Háspennumælis vakutengill Chilworth JCI 164
Háspennumælis vakutengill Chilworth JCI 164
Háspennumælis vakutengill Chilworth JCI 164
Háspennumælis vakutengill Chilworth JCI 164
Háspennumælis vakutengill Chilworth JCI 164
Háspennumælis vakutengill Chilworth JCI 164
more Images
Chilworth JCI 164
Chilworth JCI 164
Chilworth JCI 164
Chilworth JCI 164
Chilworth JCI 164
Chilworth JCI 164
Myndir sýna
Sýna kort

Upplýsingar um vélina

Heiti vélar:
Háspennumælis vakutengill
framleiðandi:
Chilworth
Gerð:
JCI 164
Ástand:
mjög gott (notað)

Verð og staðsetning

VB aukaskattur bætist við
1.600 EUR
Staðsetning:
Dunkerstrasse 29, 46325 Borken/Burlo, DE Þýskaland
Hringdu

Vélasala

Fannstu nýja vél? Nú breytir þú því gamla í peninga.
Fannstu nýja vél? Nú breytir þú því gamla í peninga. Náðu bestu verði í gegnum Machineseeker.
Meira um sölu á vélum

Tilboðsupplýsingar

Auglýsingarauðkenni:
A17570008
Tilvísunarnúmer:
21633
uppfærsla:
síðast þann 06.08.2025

Lýsing

Chilworth JCI 164 High-Voltage Adapter
General Description
The JCI 146 is a voltmeter adapter component designed for integration into broader experimental systems.

Combined with our JCI 140, the system enables the measurement of current-carrying conductors with voltages up to ±60 kV DC through direct connection with an accuracy of ±2% (nominal) and minimal loading effects on the device under test.
Dsdpfju Ehh Eex Aczjku

The high input impedance and low capacitance of the JCI 146 are suitable for more accurate DC voltage measurements.

Other conventional techniques for directly measuring high voltages (e.g., high-voltage meters, capacitive and resistive divider networks, etc.) often produce inaccurate results due to loading effects caused by the test setup.

This device can be used to verify the calibration and accuracy of high-voltage sources by power utilities, calibration test houses, and cable manufacturers, to name a few applications.

Features
Direct measurement of live conductors up to ± 60 kV DC
High-accuracy measurement with minimal loading effects
Low input capacitance
Very high input impedance, typically 10 13 ohms
Can be used in a wider range of test and research systems
Optional battery-powered and opto-isolated data acquisition module available for remote high-voltage monitoring.

Specification
Measurement:
Maximum measurement voltage ± 60 kV DC
Input impedance:
Not less than 4.7x10 13 ohms at ± 50 kV
Input capacitance:
32 pF (± 20%) (JCI 146 chamber only)
Installation:
Fixed installation (permanent ground connection required)
Use:
Used in Faraday cage environments (not included as standard)
Accuracy:
Nominal ± 2%
Attenuation: 1/10
of the reading displayed on the JCI 140

For use with the JCI 140 static monitor and the JCI 165 data acquisition module

Find more items - new and used - in our shop!
International shipping costs upon request!

Bjóðandi

Skráð frá: 2008

592 Auglýsingar á netinu

Hringdu

Senda fyrirspurn

Landus 
Þýskaland
Austurríki
Sviss
Bandaríki Norður-Ameríku
Bretland
Frakkland
Belgía
Spánn
Mexíkó
Ítalía
Holland
Pólland
Rússneska sambandsríkið
Hvítrússland (Belarus lýðveldi)
Úkraína
Eistland
Tyrkland
Nýja-Sjáland
Írland
Tékkneska lýðveldið
Danmörk
Finnland
Svíþjóð
Noregur
Lúxemborg
Grikkland
Litháen
Lettland
Ísland
Portúgal
Brasilía
Venesúela
Argentína
Ungverjaland
Slóvakía
Rúmenía
Moldóva
Slóvenía
Serbía
Svartfjallaland
Albanía
Króatía
Búlgaría
Norður-Makedónía
Bosnía og Hersegóvína
Ísrael
Egyptaland
Marokkó
Indland
Indónesía
Suður-Kórea
Japan
Taíland
Malasía
Víetnam
China
Taívan
Íran
Bangladesh
Afganistan
Athugasemd: Fyrirspurn þín verður send áfram til allra seljenda í vélaflokknum. Þannig getur þú fengið fjölda tilboða.
Fyrirspurnina tókst ekki að senda. Vinsamlegast reyndu aftur síðar.

Sími & Fax

+49 2862 ... auglýsingar