Lýsing
CTS
Type: TW -60/9
Temperature test cell water-cooled
CTS temperature test cell type TW -60/9
T means: Temperature
W means: Walk in
-60 means: lower temperature -60°C
9 means: 9 m³ test chamber volume
Technical design:
Refrigeration unit:
water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment by electronic
monitoring and control system,
environmentally friendly refrigerant R23 / R404 A
Control system:
32 bit controller
Blodpfovb E Uqex Afled
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material
control
Technical performance data:
Temperature tests:
Temperature range -60 °C to +100 °C
Temperature deviation
± 0.1 to 0.5 K in time
Average rate of temperature change with test material and
with heat radiation measured in the supply air.
Heating: 1.6 K/min from -40 °C to +85 °C
Cooling: 1.6 K/min from +85°C to -40°C
Test material 420 kg of solar cell modules with100% flow
Heat radiation 3000 Watt permanent
The technical data refer to an ambient temperature of +25 °C, nominal voltage 400
V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 9 m³
External dimensions: Width approx. 4140 mm, depth 2680 mm, height 3000 mm
Test chamber dimensions: Width approx. 1600 mm depth 2400 mm, height 2200 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, PE, 50 Hz
Rated power 48.9 kW Rated current: 74.9 A
Protection class IP 54
Cooling water connections Cooling water supply/return R1 ¼"", internal thread
Unpressurized condensate drain R1" internal thread
Weight: approx. 5609 kg
Condition: used / second-hand
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Type: TW -60/9
Temperature test cell water-cooled
CTS temperature test cell type TW -60/9
T means: Temperature
W means: Walk in
-60 means: lower temperature -60°C
9 means: 9 m³ test chamber volume
Technical design:
Refrigeration unit:
water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment by electronic
monitoring and control system,
environmentally friendly refrigerant R23 / R404 A
Control system:
32 bit controller
Blodpfovb E Uqex Afled
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material
control
Technical performance data:
Temperature tests:
Temperature range -60 °C to +100 °C
Temperature deviation
± 0.1 to 0.5 K in time
Average rate of temperature change with test material and
with heat radiation measured in the supply air.
Heating: 1.6 K/min from -40 °C to +85 °C
Cooling: 1.6 K/min from +85°C to -40°C
Test material 420 kg of solar cell modules with100% flow
Heat radiation 3000 Watt permanent
The technical data refer to an ambient temperature of +25 °C, nominal voltage 400
V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 9 m³
External dimensions: Width approx. 4140 mm, depth 2680 mm, height 3000 mm
Test chamber dimensions: Width approx. 1600 mm depth 2400 mm, height 2200 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, PE, 50 Hz
Rated power 48.9 kW Rated current: 74.9 A
Protection class IP 54
Cooling water connections Cooling water supply/return R1 ¼"", internal thread
Unpressurized condensate drain R1" internal thread
Weight: approx. 5609 kg
Condition: used / second-hand
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2012
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
Lítil auglýsing
Borken
2.072 km
Hitaprófunarklefi Inngönguprófunaraðstaða
CTSTW-60/9 -60°C bis +100°C 9m³
CTSTW-60/9 -60°C bis +100°C 9m³
Lítil auglýsing
Sonsbeck
2.075 km
Togprófunarvél alhliða prófunarvél
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Lítil auglýsing
Aschheim
2.605 km
Kæligeymslur
Vissmann
Vissmann
Lítil auglýsing
Nysa
2.635 km
Kælt herbergi 6 EUR PAL
TELEDOOR6 EUR PAL
TELEDOOR6 EUR PAL
Lítil auglýsing
Weißenhorn
2.530 km
Málmgrindur fyrir brettastæður 1m-1,2m
Lítil auglýsing
Moers
2.099 km
THERMOCONTAINER djúpfrosinn ílát
TKTC-720
TKTC-720
Lítil auglýsing
Niedźwiedź
2.834 km
Kæli-/frystiklefi
Komora chłodnicza/mroźnicza ILKAZELL345x320x245 cm
Komora chłodnicza/mroźnicza ILKAZELL345x320x245 cm
Lítil auglýsing
Freising
2.585 km
Kæliklefi með kælieiningu
Lítil auglýsing
Niedźwiedź
2.834 km
Kæli-/frystiklefi
Komora chłodnicza mroźnicza Viessmann330 x 270 x 225 cm
Komora chłodnicza mroźnicza Viessmann330 x 270 x 225 cm
Lítil auglýsing
Borken
2.072 km
Loftslagsprófunarskápar 800 L, -55°C til +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
WeissClimeEvent C/800/55a/25/S 25K/min
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp