SprautumótunarvélENGEL
VICTORY 200/60 Power
Sprautumótunarvél
ENGEL
VICTORY 200/60 Power
Framleiðsluár
2003
Ástand
Notað
Staðsetning
Škofja Loka 

Upplýsingar um vélina
- Heiti vélar:
- Sprautumótunarvél
- Framleiðandi:
- ENGEL
- Gerð:
- VICTORY 200/60 Power
- Framleiðsluár:
- 2003
- Ástand:
- notaður
- Vinnustundir:
- 6.500 h
Verð og staðsetning
- Staðsetning:
- Trata 49, 4220 Škofja Loka, Slovenija

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A22085988
- Uppfærsla:
- síðast þann 09.06.2026
Lýsing
VICTORY 200/60 Power
SN 162699
Closing force (kN) 600 (expandable to 800 kN)
Year of manufacture: 2003
Screw diameter 30.00 mm, L/D ratio of the mixing cylinder 20.50
Operating hours: ONLY 6,500
Vertically enlarged clamping plates (B-plates)
Swiveling reject chute for reject selection, activated upon reject detection
Version variant HV 2 with control pumps (pressure and flow control in a closed-loop control system)
for parallel movement sequence
Microcomputer CC100 A03
Kistler 5155 A2213Q02 charge amplifier with automatic switching pressure detection
4x digital output, 4x digital input
Interface for temperature control units or hot runner controllers
Dkodpfx Aezcanfokcjn
Data protocol Engel, physical type 20 mA – CL
Microflow
MINI-CAM - Process parameter adjustment support based on an expert system
1x service socket, 2-pole, 230V
4x 3-phase socket, 10A / 16A
2x 3-phase socket, 10A / 16A, switchable
2/2-way solenoid air valve, R1/4 inch
Flow regulator 0-10 l, 8 circuits
Temperature control circuits can be switched off manually or automatically (centrally at the flow controller) – Switch-off function selectable.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
SN 162699
Closing force (kN) 600 (expandable to 800 kN)
Year of manufacture: 2003
Screw diameter 30.00 mm, L/D ratio of the mixing cylinder 20.50
Operating hours: ONLY 6,500
Vertically enlarged clamping plates (B-plates)
Swiveling reject chute for reject selection, activated upon reject detection
Version variant HV 2 with control pumps (pressure and flow control in a closed-loop control system)
for parallel movement sequence
Microcomputer CC100 A03
Kistler 5155 A2213Q02 charge amplifier with automatic switching pressure detection
4x digital output, 4x digital input
Interface for temperature control units or hot runner controllers
Dkodpfx Aezcanfokcjn
Data protocol Engel, physical type 20 mA – CL
Microflow
MINI-CAM - Process parameter adjustment support based on an expert system
1x service socket, 2-pole, 230V
4x 3-phase socket, 10A / 16A
2x 3-phase socket, 10A / 16A, switchable
2/2-way solenoid air valve, R1/4 inch
Flow regulator 0-10 l, 8 circuits
Temperature control circuits can be switched off manually or automatically (centrally at the flow controller) – Switch-off function selectable.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Síðast á netinu: Í dag
Skráð frá: 2021
10 Auglýsingar á netinu
Senda fyrirspurn
Sími & Fax
+386 31 7... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp