VarmaskiptirEvapco Air Solutions a/s
TKZ Heat Exchanger
Varmaskiptir
Evapco Air Solutions a/s
TKZ Heat Exchanger
FCA VB aukaskattur bætist við
2.500 EUR
Framleiðsluár
2018
Ástand
Notað
(fullkomlega virkur)
Staðsetning
Bergen op Zoom 

Grunnupplýsingar
- Heiti vélar:
- Varmaskiptir
- Framleiðandi:
- Evapco Air Solutions a/s
- Gerð:
- TKZ Heat Exchanger
- Framleiðsluár:
- 2018
- Ástand:
- tilbúinn til notkunar (notaður)
- Virkni:
- fullkomlega virkur
Verð og staðsetning
FCA VB aukaskattur bætist við
2.500 EUR
- Staðsetning:
- Bergen op Zoom, Holland

Hringdu
Tæknilegar upplýsingar
Vökvaknúð kerfi
Rekstrarþrýstingur:
10 stöng
Upplýsingar um afl
Inngangsspenna:
400 V
Inngangstíðni:
50 Hz
Innstreymisstraumur:
3 A
Inntakstraumsgerð:
þriggja fasa
Skjöl og vottun
Gerðarmerki fáanlegt
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A23348684
- Uppfærsla:
- síðast þann 17.11.2026
Lýsing
The model designation EVAPCO TKZ-700-800-7-20-2.0-B5 refers to a custom-made finned heat exchanger.
Explanation of the model code:
• TKZ (series/design). Indicates the specific coil or design series – dry cooler.
• 700 (coil height/width in mm). Indicates the finned height (or width) of the heat exchanger block, which is 700 mm.
• 800 (coil length in mm). Indicates the finned length (tube length) of the coil, which is 800 mm.
• 7 (tube rows). Indicates the number of tube rows arranged one behind the other in the direction of airflow (7 rows).
Ksdps Akvrpofx Ac Eend
• 20 (circuits). Typically indicates the number of parallel tube circuits or the tube spacing.
• 2.0 (fin spacing in mm). Indicates the distance between the individual heat exchanger fins (2.0 mm), which is typical for applications where ice formation or increased dirt accumulation is possible.
The operating hours are unknown, but are assumed to be low, as the heat exchanger was used in a research and development laboratory.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Explanation of the model code:
• TKZ (series/design). Indicates the specific coil or design series – dry cooler.
• 700 (coil height/width in mm). Indicates the finned height (or width) of the heat exchanger block, which is 700 mm.
• 800 (coil length in mm). Indicates the finned length (tube length) of the coil, which is 800 mm.
• 7 (tube rows). Indicates the number of tube rows arranged one behind the other in the direction of airflow (7 rows).
Ksdps Akvrpofx Ac Eend
• 20 (circuits). Typically indicates the number of parallel tube circuits or the tube spacing.
• 2.0 (fin spacing in mm). Indicates the distance between the individual heat exchanger fins (2.0 mm), which is typical for applications where ice formation or increased dirt accumulation is possible.
The operating hours are unknown, but are assumed to be low, as the heat exchanger was used in a research and development laboratory.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Síðast á netinu: í síðustu viku
Skráð frá: 2026
19 Auglýsingar á netinu
Senda fyrirspurn
Sími & Fax
+43 660 2... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp