Fresenius Vial Pilot A2 læknisfræðileg innrennslis- og sprautudæla, perfúsorFresenius
Pilot A2
Fresenius Vial Pilot A2 læknisfræðileg innrennslis- og sprautudæla, perfúsor
Fresenius
Pilot A2
VB aukaskattur bætist við
226 EUR
Ástand
Notað
Staðsetning
Borken 

Verð og staðsetning
VB aukaskattur bætist við
226 EUR
- Staðsetning:
- Borken, Þýskaland

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A23232142
- Tilvísunarnúmer:
- 74859
- Uppfærsla:
- síðast þann 28.10.2026
Lýsing
Fresenius Pilot A2 Syringe Pump
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In medical practice, the device is used for the continuous, precisely controlled administration of highly potent drugs, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for rate indication, and automatic safety and alarm functions.
Thanks to the pre-mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (pre-settings for BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for accurate rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery level.
- Mobility: Integrated battery for bridging patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Power supply: Mains operation: 230 V ~ 50/60 Hz
Nedpfj Af Uyrjx Amkown
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety functions: Acoustic and visual alarm systems (e.g., for occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2011
"Everything from one source: We would be happy to offer you a suitable bank financing option for your project."
More items - new and used - can be found in our shop!
International shipping costs on request!
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In medical practice, the device is used for the continuous, precisely controlled administration of highly potent drugs, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for rate indication, and automatic safety and alarm functions.
Thanks to the pre-mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (pre-settings for BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for accurate rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery level.
- Mobility: Integrated battery for bridging patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Power supply: Mains operation: 230 V ~ 50/60 Hz
Nedpfj Af Uyrjx Amkown
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety functions: Acoustic and visual alarm systems (e.g., for occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2011
"Everything from one source: We would be happy to offer you a suitable bank financing option for your project."
More items - new and used - can be found in our shop!
International shipping costs on request!
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Síðast á netinu: í síðustu viku
Skráð frá: 2008
536 Auglýsingar á netinu
Senda fyrirspurn
Sími & Fax
+49 2862 ... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
Fullgengt
Skilaboðin þín hafa verið send.
Lítil auglýsing
Borken
2.064 km
Fresenius Vial Pilot A2 læknisfræðileg innrennslis- og sprautudæla (Perfusor)
FreseniusPilot A2
FreseniusPilot A2
Fullgengt
Skilaboðin þín hafa verið send.
Lítil auglýsing
Borken
2.064 km
Fresenius Vial Pilot A2 lækningadæla fyrir innrennsli og sprautur, Perfusor b
FreseniusPilot A2
FreseniusPilot A2
Fullgengt
Skilaboðin þín hafa verið send.
Lítil auglýsing
Borken
2.064 km
Fresenius Vial Pilot A2 lækningainnrennslisdæla með sprautu, perfusor
FreseniusPilot A2
FreseniusPilot A2
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp