Uppgufunartæki GEA KÜBA MEÐ 1 viftuGEA KÜBA
CA.E.06-1X1F
Uppgufunartæki GEA KÜBA MEÐ 1 viftu
GEA KÜBA
CA.E.06-1X1F
FCA VB aukaskattur bætist við
1.200 EUR
framleiðsluár
2007
Ástand
Notað
Staðsetning
Oradea 

Myndir sýna
Sýna kort
Upplýsingar um vélina
- Heiti vélar:
- Uppgufunartæki GEA KÜBA MEÐ 1 viftu
- framleiðandi:
- GEA KÜBA
- Gerð:
- CA.E.06-1X1F
- Vélar númer:
- 2514070/0200/2007/15128743/1
- framleiðsluár:
- 2007
- Ástand:
- mjög gott (notað)
Verð og staðsetning
FCA VB aukaskattur bætist við
1.200 EUR
- Staðsetning:
- Calea Aradului, nr. 23 Bl. P64, ap. 39, 410223 Oradea, RO
Hringdu
Vélasala

Hefur þú þegar auglýst notaða vélina þína?
Seldu í gegnum Machineseeker án þóknunar.
Meira um sölu á vélum
Meira um sölu á vélum
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A7765472
- Tilvísunarnúmer:
- UBB 02
- uppfærsla:
- síðast þann 20.07.2024
Lýsing
Used evaporator GEA KÜBA, typ CA.E.06-1X1F, serial no. 2514070/0200/2007/15128743/1
Year of manufacture 2007
Casing Self-supporting construction, fan sections individually partitioned. Ventilator extremely silent (E)• Casing and legs from galvanized sheet steel • Temperature- and UV-radiation resistant powder coating RAL 7032 pebble gray • Lifting hangers standard
Heat exchanger Standard tube arrangement lengthwise, staggered, in special copper. • Tubing: Tubes: Ripple Fin, SF-Cu Fins: High performance aluminum fins with Al studs for increased heat transfer Fin spacing: 2,2 mm. • Multi-circuiting possible. • Fluid connections Brazed copper connection vertical (can be used with vertical and horizontal airflow). 3. Axial fans Compact unit without external pressure, corrosion proof and weather resistant: Motor with fans, Fan guard in accordance with DIN 31001/24167 and assembly brackets. • Fan blades ø 650 mm, balanced in two levels according to a VDI 2060 standard. • Motors, threephase current 400±10%V, 50 Hz, 2 speeds, ∆-Y-connections, Protection: ø 650, IP66 • variable speed control by reduction of voltage. • Proof to frequency changes (maximum fan pitch dU/dt=500V/µs;
Standard protection of motor by thermocouples. • For outdoor installation and ambient motor temperatures of -30°C up to +60°C.
CA. 05 – 06 • 400V±10%V-3 with speed reduction ∆-Y-change-over • Protection CA.06: IP66 • Range of application: –30°C to +60°C • 230V±10%V-1 on request
Maximum permissible 60 starts per hour. Fan motors have to be operated for at least two hours per month. • Other motors will change performance and Sound Pressure Levels quoted.
The standard fans are recommended for frequency converters with a: • clock frequency: < 16kHz • voltage speed increase : , dU/dt < 1000V • frequency: f < 60Hz For reduction of peak voltages, speed voltage increase and motor noise (at reduced speed) manufacturers of frequency converters recommend the use of sinus filters at the output, especially when using motor cables longer than 50 m. For shorter motor cables dU/dt motor reactors can be used for this purpose. If several motors are connected, the total of all cable lengths has to be considered. Taking electromagnetic compatibility guidelines into consideration, power chokes or input filters are to be used at the input side (and shielded cables having a proper ground connection are to be used)
LxBxH: 141 х 115 х 114 cm; Colant R typ
Very good condition
Price Euro 1200 Euro + VAT, negotiable, FCA: Oradea/Romania
Irrtum, Anderungen und Zwischenverkauf vorbehalten /
Subject to errors, changes and prior sale /
Ne rezervăm dreptul la greșeli, modificări și vânzare
Godpfx Asip Utaodkjbu
We speak English. /Wir sprechen Deutsch./ Beszélünk magyarul. /Nous parlons français/Vorbim romana
Year of manufacture 2007
Casing Self-supporting construction, fan sections individually partitioned. Ventilator extremely silent (E)• Casing and legs from galvanized sheet steel • Temperature- and UV-radiation resistant powder coating RAL 7032 pebble gray • Lifting hangers standard
Heat exchanger Standard tube arrangement lengthwise, staggered, in special copper. • Tubing: Tubes: Ripple Fin, SF-Cu Fins: High performance aluminum fins with Al studs for increased heat transfer Fin spacing: 2,2 mm. • Multi-circuiting possible. • Fluid connections Brazed copper connection vertical (can be used with vertical and horizontal airflow). 3. Axial fans Compact unit without external pressure, corrosion proof and weather resistant: Motor with fans, Fan guard in accordance with DIN 31001/24167 and assembly brackets. • Fan blades ø 650 mm, balanced in two levels according to a VDI 2060 standard. • Motors, threephase current 400±10%V, 50 Hz, 2 speeds, ∆-Y-connections, Protection: ø 650, IP66 • variable speed control by reduction of voltage. • Proof to frequency changes (maximum fan pitch dU/dt=500V/µs;
Standard protection of motor by thermocouples. • For outdoor installation and ambient motor temperatures of -30°C up to +60°C.
CA. 05 – 06 • 400V±10%V-3 with speed reduction ∆-Y-change-over • Protection CA.06: IP66 • Range of application: –30°C to +60°C • 230V±10%V-1 on request
Maximum permissible 60 starts per hour. Fan motors have to be operated for at least two hours per month. • Other motors will change performance and Sound Pressure Levels quoted.
The standard fans are recommended for frequency converters with a: • clock frequency: < 16kHz • voltage speed increase : , dU/dt < 1000V • frequency: f < 60Hz For reduction of peak voltages, speed voltage increase and motor noise (at reduced speed) manufacturers of frequency converters recommend the use of sinus filters at the output, especially when using motor cables longer than 50 m. For shorter motor cables dU/dt motor reactors can be used for this purpose. If several motors are connected, the total of all cable lengths has to be considered. Taking electromagnetic compatibility guidelines into consideration, power chokes or input filters are to be used at the input side (and shielded cables having a proper ground connection are to be used)
LxBxH: 141 х 115 х 114 cm; Colant R typ
Very good condition
Price Euro 1200 Euro + VAT, negotiable, FCA: Oradea/Romania
Irrtum, Anderungen und Zwischenverkauf vorbehalten /
Subject to errors, changes and prior sale /
Ne rezervăm dreptul la greșeli, modificări și vânzare
Godpfx Asip Utaodkjbu
We speak English. /Wir sprechen Deutsch./ Beszélünk magyarul. /Nous parlons français/Vorbim romana
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2018
Senda fyrirspurn
Sími & Fax
+40 359 1... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp