Modular himnu síunareiningGEA
Membrane Skid up to 6.25 m³/h
Modular himnu síunareining
GEA
Membrane Skid up to 6.25 m³/h
Framleiðsluár
2013
Ástand
Notað
Staðsetning
Liestal 

Upplýsingar um vélina
- Heiti vélar:
- Modular himnu síunareining
- Framleiðandi:
- GEA
- Framleiðsluár:
- 2013
- Ástand:
- mjög gott (notað)
Verð og staðsetning
- Staðsetning:
- 4410 Liestal, Schweiz

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A18024946
- Uppfærsla:
- síðast þann 21.02.2025
Lýsing
GEA Modular Membrane Filtration System up to 6.25 m³/h, in excellent condition and barely used. This equipment was used for just two validation batches, and after that has been in storage. It is currently equipped with spiral-wound nanofiltration membranes but other membrane types can be used for microfiltration (MF), ultrafiltration (UF), etc.
The complete original manufacturer documentation is included in digital format, comprising the operating manual, process flow charts, wiring diagrams, certificates, inspection reports, and other relevant technical documentation.
The system is designed to process a maximum volume of approximately 100 m³ of product (feed) per day. An average feed flow rate of approximately 4 to 6 m³/h is assumed under the “16/4” or “20/4” operating regime (Explanation: “20/4” corresponds to 20 hours of filtration operation / 4 hours of CIP cleaning).
If, at a later stage, the daily processing capacity needs to be increased or the installed membrane surface becomes insufficient due to unforeseeable fouling effects, two empty slots are provided for retrofitting additional membrane housings. The piping and recirculation pump are already prepared for such an expansion.
The membrane unit is designed for a semi-automatic cleaning-in-place (CIP) procedure. The system includes the required valves for internal circulation of cleaning solutions, followed by system flushing.
Specifications
- Feed volume: 400 - 500 m³/week
- Feed volume: 80 - 100 m³/day
- Feed volume: 4.0 - 6.25 m³/h
Ppjdsvhctwjpfx Ah Hst
- Production time: 16 - 20 h/day
- Operating temperature: 35 to max. 65 °C
Consumption
- Power supply (pumps): 3 x 400 V, 50 Hz
- Installed power: approx. 65 kW
- Electric power consumption: 53.1 kW/h
- Compressed air: 6 bar, oil- and water-free
- Steam: 6 bar (max.)
- Seal water: approx. 75 - 150 l/h
- CIP water: approx. 19 m³/h
- CIP water per cycle: 6 m³/CIP
- Steam consumption per cycle: 100 kg/CIP
- CIP chemicals: (e.g., membrane cleaner, acid, alkali, preservative, biocide)
Limits
- Max. operating temperature: 65 °C
- Max. operating pressure: 30 bar
- pH range for feed water:
- Maximum: pH 10.0
- Minimum: pH 2.0
Cleaning-in-Place (CIP)
- Max. temperature: 85 °C
- Max. pressure: 10 bar
- pH limits (for up to 30 minutes):
- Maximum: pH 10.5
- Minimum: pH 2.0
The complete original manufacturer documentation is included in digital format, comprising the operating manual, process flow charts, wiring diagrams, certificates, inspection reports, and other relevant technical documentation.
The system is designed to process a maximum volume of approximately 100 m³ of product (feed) per day. An average feed flow rate of approximately 4 to 6 m³/h is assumed under the “16/4” or “20/4” operating regime (Explanation: “20/4” corresponds to 20 hours of filtration operation / 4 hours of CIP cleaning).
If, at a later stage, the daily processing capacity needs to be increased or the installed membrane surface becomes insufficient due to unforeseeable fouling effects, two empty slots are provided for retrofitting additional membrane housings. The piping and recirculation pump are already prepared for such an expansion.
The membrane unit is designed for a semi-automatic cleaning-in-place (CIP) procedure. The system includes the required valves for internal circulation of cleaning solutions, followed by system flushing.
Specifications
- Feed volume: 400 - 500 m³/week
- Feed volume: 80 - 100 m³/day
- Feed volume: 4.0 - 6.25 m³/h
Ppjdsvhctwjpfx Ah Hst
- Production time: 16 - 20 h/day
- Operating temperature: 35 to max. 65 °C
Consumption
- Power supply (pumps): 3 x 400 V, 50 Hz
- Installed power: approx. 65 kW
- Electric power consumption: 53.1 kW/h
- Compressed air: 6 bar, oil- and water-free
- Steam: 6 bar (max.)
- Seal water: approx. 75 - 150 l/h
- CIP water: approx. 19 m³/h
- CIP water per cycle: 6 m³/CIP
- Steam consumption per cycle: 100 kg/CIP
- CIP chemicals: (e.g., membrane cleaner, acid, alkali, preservative, biocide)
Limits
- Max. operating temperature: 65 °C
- Max. operating pressure: 30 bar
- pH range for feed water:
- Maximum: pH 10.0
- Minimum: pH 2.0
Cleaning-in-Place (CIP)
- Max. temperature: 85 °C
- Max. pressure: 10 bar
- pH limits (for up to 30 minutes):
- Maximum: pH 10.5
- Minimum: pH 2.0
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2023
8 Auglýsingar á netinu
Senda fyrirspurn
Sími & Fax
+41 61 50... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
Lítil auglýsing
Dinkelscherben
2.548 km
Flatt færiband uppfyllir FDA matvæli
die magnetrofis GmbH & Co. KGFlachförderband FDA
die magnetrofis GmbH & Co. KGFlachförderband FDA
Lítil auglýsing
Babenhausen
2.329 km
Rjómaeldavél
MicaCK 60 NEU
MicaCK 60 NEU
Lítil auglýsing
Danmörk
1.811 km
Framleiðsla mjólkur og mjólkurvara
Alfa Laval BactofugeMRPX 418SGV-34C
Alfa Laval BactofugeMRPX 418SGV-34C
Lítil auglýsing
Thisted
1.722 km
Snúningsdæla JEC
JEC-PumpZF -120-021
JEC-PumpZF -120-021
Lítil auglýsing
Almagro
3.067 km
Gufuketill
ATTSURL-3000/8
ATTSURL-3000/8
Lítil auglýsing
Þýskaland
2.280 km
Mjólkurtöppunarlína
ElopakPS 50
ElopakPS 50
Lítil auglýsing
Kreuzau
2.158 km
Hræringar- og blöndunarbúnaður
StephanUMC 12
StephanUMC 12
Lítil auglýsing
Suffolk
1.804 km
Pokafyllingarvél
Toyo JidokiTT-8
Toyo JidokiTT-8
Lítil auglýsing
Menslage
2.038 km
ALWID ATEX áfyllingarlína (2021)
ALWIDAbfülllinie
ALWIDAbfülllinie
Lítil auglýsing
Thisted
1.722 km
Mjólkur- og mjólkurframleiðslu
APVType PCI-UF 50-100
APVType PCI-UF 50-100
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp