LC-bakka afgasunarklefiGMC
LC-tray degassing cham
LC-bakka afgasunarklefi
GMC
LC-tray degassing cham
Framleiðsluár
2020
Ástand
Notað
Staðsetning
Maasmechelen 

Myndir sýna
Sýna kort
Upplýsingar um vélina
- Heiti vélar:
- LC-bakka afgasunarklefi
- Framleiðandi:
- GMC
- Framleiðsluár:
- 2020
- Ástand:
- næstum eins og nýtt (notað)
- Virkni:
- fullkomlega virkur
Verð og staðsetning
- Staðsetning:
- Breitwatertraat 22, 3630 Maasmechelen, Belgique

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A19176916
- Uppfærsla:
- síðast þann 11.02.2026
Lýsing
LC-tray degassing chamber
2. Degassing Chamber:
1. Vacuum profile;
1.1. Pressure set points freely adjustable between 1.103 and 1.10-3 mBar
1.1.1. Measurement range: 1.103 – 5.10-4
1.2. Time set points freely adjustable between 1 and 600 min per step
1.2.1. Degassing step (D) can range from minutes to days
1.3. Evacuation and ventilation rates must be controllable
Bedpfx Aswliryjd Dscw
1.4. The evacuation cycle (A – D) is executed automatically
1.4.1. The venting step (E) must be manually activated (operator)
1.5. Typical degassing profile
An LC-tray degassing chamber is a specialized vacuum chamber designed to remove trapped air and dissolved gases from liquid materials (such as Liquid Crystals or "LC liquid") contained in a tray. This process ensures that the material is free from bubbles prior to further processing, which is critical for the quality and reliability of electronic components and displays.
Core Functionality
- Controlled Vacuum Environment: The system generates a vacuum, reducing the pressure above the liquid, which forces trapped gas bubbles to rise and escape.
- Precision Profiles: High-end units provide freely adjustable pressure set points (e.g., between 1×10³ and 1×10⁻³ mBar) and time cycles (from minutes up to several days) to suit different material viscosities and process requirements.
- Automated Cycles: Evacuation cycles are performed automatically, while venting is manually controlled to prevent liquid agitation or sudden movement.
Key Components & Features
- Chamber Construction: Usually constructed from 304 stainless steel or polished aluminum to ensure high vacuum resistance, durability, and easy cleaning, thereby reducing the risk of contamination.
- LC-Tray Drawer: Special drawer or adaptation system ensures easy loading and unloading. It is vital that the tray stays perfectly level (waterpas) to avoid liquid spillage.
- Monitoring Window: A thick, transparent lid (often made from acrylic) or viewing panel enables operators to monitor the liquid surface and bubble behavior during the process.
- Cleanliness Standards: Interior surfaces are highly polished to prevent moisture retention and ensure no contamination by chamber materials.
Typical Specifications (Based on industrial models such as GMC/Masevon):
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
2. Degassing Chamber:
1. Vacuum profile;
1.1. Pressure set points freely adjustable between 1.103 and 1.10-3 mBar
1.1.1. Measurement range: 1.103 – 5.10-4
1.2. Time set points freely adjustable between 1 and 600 min per step
1.2.1. Degassing step (D) can range from minutes to days
1.3. Evacuation and ventilation rates must be controllable
Bedpfx Aswliryjd Dscw
1.4. The evacuation cycle (A – D) is executed automatically
1.4.1. The venting step (E) must be manually activated (operator)
1.5. Typical degassing profile
An LC-tray degassing chamber is a specialized vacuum chamber designed to remove trapped air and dissolved gases from liquid materials (such as Liquid Crystals or "LC liquid") contained in a tray. This process ensures that the material is free from bubbles prior to further processing, which is critical for the quality and reliability of electronic components and displays.
Core Functionality
- Controlled Vacuum Environment: The system generates a vacuum, reducing the pressure above the liquid, which forces trapped gas bubbles to rise and escape.
- Precision Profiles: High-end units provide freely adjustable pressure set points (e.g., between 1×10³ and 1×10⁻³ mBar) and time cycles (from minutes up to several days) to suit different material viscosities and process requirements.
- Automated Cycles: Evacuation cycles are performed automatically, while venting is manually controlled to prevent liquid agitation or sudden movement.
Key Components & Features
- Chamber Construction: Usually constructed from 304 stainless steel or polished aluminum to ensure high vacuum resistance, durability, and easy cleaning, thereby reducing the risk of contamination.
- LC-Tray Drawer: Special drawer or adaptation system ensures easy loading and unloading. It is vital that the tray stays perfectly level (waterpas) to avoid liquid spillage.
- Monitoring Window: A thick, transparent lid (often made from acrylic) or viewing panel enables operators to monitor the liquid surface and bubble behavior during the process.
- Cleanliness Standards: Interior surfaces are highly polished to prevent moisture retention and ensure no contamination by chamber materials.
Typical Specifications (Based on industrial models such as GMC/Masevon):
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Senda fyrirspurn
Sími & Fax
+32 89 53... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
Lítil auglýsing
Achern
2.415 km
Press eining límdur geisla
SCHWÖRERHydraulisch
SCHWÖRERHydraulisch
Lítil auglýsing
Þýskaland
2.341 km
Rafall
MOSAGE 3000 SX
MOSAGE 3000 SX
Lítil auglýsing
Forst
2.388 km
60.000 lítrar / 60 m³ slökkvivatnstankur
Lítil auglýsing
Roreto
2.795 km
Lengdarskurðarsög (kljúfur) til að rifa
BIESSE - GMCSpliter 4-84 L
BIESSE - GMCSpliter 4-84 L
Lítil auglýsing
Diespeck
2.427 km
Vörubíll með fleti og presennu
MANTGX 26.480 LL 6x2 Nachlauflenkachse
MANTGX 26.480 LL 6x2 Nachlauflenkachse
Lítil auglýsing
Wiefelstede
1.998 km
Viftublásari
unbekannt2HO2294D AMR075E1 Lüfterrad Ø 350/215 mm
unbekannt2HO2294D AMR075E1 Lüfterrad Ø 350/215 mm
Lítil auglýsing
Wiefelstede
1.998 km
Blásari 220/380 V
unbekannt295/250/H320 mm
unbekannt295/250/H320 mm
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp