Lýsing
The technical condition is very good, and the device has been tested.
This means that the devices are calibrated, perform 100% accurate measurements, and are regularly warmed up for at least 12 hours once a month.
Fgjdjzcmbljpfx Acrec
It is possible to perform an on-site transformer oil test – of course, after initial verification to compare the results, as shown in the photos.
The MYRKOS chromatograph performs the analysis of concentrations of gases dissolved in insulating oil (DGA). It allows for the detection of developing faults in power transformers and other equipment containing insulating oils (chokes, current transformers).
It also allows for the analysis of gas extracted from a Buchholz relay!
The MYRKOS chromatograph is extremely accurate, compact, and provides complete coverage for the relevant concentrations of fault gases in the oil.
A gas standard (a cylinder with calibration gas) ensures measurement consistency with concentration standards. Before performing a measurement, the device is always calibrated, and its functionality is checked. A special shaking syringe (included) ensures the correct volume ratio. An excellent solution for oil laboratories in power plants and research facilities serving the power industry. PPMReport software with a Polish language version is included. It has built-in diagnostic tools: Duval's triangle and Rogers' ratios.
Used by power plants, system operators, and laboratories serving the power and industrial sectors. The field version is equipped with a special pressure vessel for helium carrier gas (purity 99.999%). It is supplied with shaking syringes for preparing the extraction gas cushion, syringes for calibration, and an air sample.
TECHNICAL PARAMETERS
Number of gas types: 9 (Hydrogen H2, Methane CH4, Ethane C2H6, Ethylene C2H4, Acetylene C2H2, Carbon monoxide CO, Carbon dioxide C02, Oxygen 02, Nitrogen N2)
Measurement range for gas concentrations in oil: H2: 5-60,000 ppm, Other gases: 1-60,000 ppm, 02: 60 ppm - 100,000 ppm, N2: 500 ppm - 100,000 ppm
: 1050 mm
3. TECHNICAL DESCRIPTION
Gas chromatograph for testing insulating oils using the DGA (Dissolved Gas Analysis) method, for field and laboratory applications. The laboratory version includes a shaker. The MYRKOS chromatograph performs the analysis of concentrations of gases dissolved in insulating oil (DGA). It allows for the detection of developing faults in power transformers and other equipment containing insulating oils (chokes, current transformers). It also allows for the analysis of gas extracted from a Buchholz relay. The MYRKOS chromatograph is extremely accurate, compact, and provides complete coverage for the relevant concentrations of fault gases in the oil.
The condition is very good.
We have two identical, fully functional units. If you purchase both, the price of one will be 50% lower.
Before purchasing, I recommend inspecting and testing the equipment on-site (performing a test). The last test was performed on November 21, 2025, and compared with another MYRKOS device (the test was verified in a certified laboratory).
Available for viewing in Rzeszów.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
This means that the devices are calibrated, perform 100% accurate measurements, and are regularly warmed up for at least 12 hours once a month.
Fgjdjzcmbljpfx Acrec
It is possible to perform an on-site transformer oil test – of course, after initial verification to compare the results, as shown in the photos.
The MYRKOS chromatograph performs the analysis of concentrations of gases dissolved in insulating oil (DGA). It allows for the detection of developing faults in power transformers and other equipment containing insulating oils (chokes, current transformers).
It also allows for the analysis of gas extracted from a Buchholz relay!
The MYRKOS chromatograph is extremely accurate, compact, and provides complete coverage for the relevant concentrations of fault gases in the oil.
A gas standard (a cylinder with calibration gas) ensures measurement consistency with concentration standards. Before performing a measurement, the device is always calibrated, and its functionality is checked. A special shaking syringe (included) ensures the correct volume ratio. An excellent solution for oil laboratories in power plants and research facilities serving the power industry. PPMReport software with a Polish language version is included. It has built-in diagnostic tools: Duval's triangle and Rogers' ratios.
Used by power plants, system operators, and laboratories serving the power and industrial sectors. The field version is equipped with a special pressure vessel for helium carrier gas (purity 99.999%). It is supplied with shaking syringes for preparing the extraction gas cushion, syringes for calibration, and an air sample.
TECHNICAL PARAMETERS
Number of gas types: 9 (Hydrogen H2, Methane CH4, Ethane C2H6, Ethylene C2H4, Acetylene C2H2, Carbon monoxide CO, Carbon dioxide C02, Oxygen 02, Nitrogen N2)
Measurement range for gas concentrations in oil: H2: 5-60,000 ppm, Other gases: 1-60,000 ppm, 02: 60 ppm - 100,000 ppm, N2: 500 ppm - 100,000 ppm
: 1050 mm
3. TECHNICAL DESCRIPTION
Gas chromatograph for testing insulating oils using the DGA (Dissolved Gas Analysis) method, for field and laboratory applications. The laboratory version includes a shaker. The MYRKOS chromatograph performs the analysis of concentrations of gases dissolved in insulating oil (DGA). It allows for the detection of developing faults in power transformers and other equipment containing insulating oils (chokes, current transformers). It also allows for the analysis of gas extracted from a Buchholz relay. The MYRKOS chromatograph is extremely accurate, compact, and provides complete coverage for the relevant concentrations of fault gases in the oil.
The condition is very good.
We have two identical, fully functional units. If you purchase both, the price of one will be 50% lower.
Before purchasing, I recommend inspecting and testing the equipment on-site (performing a test). The last test was performed on November 21, 2025, and compared with another MYRKOS device (the test was verified in a certified laboratory).
Available for viewing in Rzeszów.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Síðast á netinu: Í dag
Skráð frá: 2025
3 Auglýsingar á netinu
Senda fyrirspurn
Sími & Fax
+48 607 6... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp