Aukakyndil sem knúinn er náttúrulegu gasiNatural Gas Fired Auxiliary Boiler
Aukakyndil sem knúinn er náttúrulegu gasi
Natural Gas Fired Auxiliary Boiler
Framleiðsluár
2024
Ástand
Nýtt
Staðsetning
Ítalía 

Myndir sýna
Sýna kort
Upplýsingar um vélina
- Heiti vélar:
- Aukakyndil sem knúinn er náttúrulegu gasi
- Framleiðandi:
- Natural Gas Fired Auxiliary Boiler
- Framleiðsluár:
- 2024
- Ástand:
- nýtt
Verð og staðsetning
- Staðsetning:
- Italy

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A21080392
- Uppfærsla:
- síðast þann 27.01.2026
Lýsing
New /Unused 2024 Natural Gas Fired Auxiliary Boiler pre-assembled in a base frame (skid)
Fuel Gas Pressure Reducing Station PRS, installed upstream the skid to reduce gas pressure from inlet pressure of 0.5 to 1.5 Bar (g) to 0.3 Bar (g).
• Once-through type steam generator with single fuel burner, feedwater pumps, Ignition System and Flame Detection System, pressure safety valve, Steam water Separator etc.
• Electrical Steam Super-Heater
• Local Control Panel installed on the skid consisting of Burner Management System, Programmable Logic Controller PLC and motor starters
Njdsydmmkepfx Ab Tjkt
• Chemical Dosing System
• Atmospheric Blow Down Tank
• Flue gas duct and stack installed outside the skid close to the Steam generator.
Auxiliary Boiler is designed for:
• Steam Flow: kg/s 1.2
• Steam Pressure: bar a 12
• Steam Temperature: 195°C
• Design Pressure: Bar g24
• Design Temperature: 343°C
• Design Code: ASME/Supplier Std.
Fuel Gas Pressure Reducing Station PRS, installed upstream the skid to reduce gas pressure from inlet pressure of 0.5 to 1.5 Bar (g) to 0.3 Bar (g).
• Once-through type steam generator with single fuel burner, feedwater pumps, Ignition System and Flame Detection System, pressure safety valve, Steam water Separator etc.
• Electrical Steam Super-Heater
• Local Control Panel installed on the skid consisting of Burner Management System, Programmable Logic Controller PLC and motor starters
Njdsydmmkepfx Ab Tjkt
• Chemical Dosing System
• Atmospheric Blow Down Tank
• Flue gas duct and stack installed outside the skid close to the Steam generator.
Auxiliary Boiler is designed for:
• Steam Flow: kg/s 1.2
• Steam Pressure: bar a 12
• Steam Temperature: 195°C
• Design Pressure: Bar g24
• Design Temperature: 343°C
• Design Code: ASME/Supplier Std.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2023
Senda fyrirspurn
Sími & Fax
+44 1273 ... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp