Loftslagskassi - hreint rýmiPK-Kältetechnik - Clean or Climate rooms
Climate - Clean room
Loftslagskassi - hreint rými
PK-Kältetechnik - Clean or Climate rooms
Climate - Clean room
framleiðsluár
2018
Ástand
Notað
Staðsetning
Maasmechelen 

Myndir sýna
Sýna kort
Upplýsingar um vélina
- Heiti vélar:
- Loftslagskassi - hreint rými
- framleiðandi:
- PK-Kältetechnik - Clean or Climate rooms
- Gerð:
- Climate - Clean room
- framleiðsluár:
- 2018
- Ástand:
- næstum eins og nýtt (notað)
- virkni:
- fullkomlega virkur
Verð og staðsetning
- Staðsetning:
- Breitwatertraat 22, 3630 Maasmechelen, BE
Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A19631221
- Tilvísunarnúmer:
- S-LTD-325
- uppfærsla:
- síðast þann 18.08.2025
Lýsing
PK clima – Clean Rooms
We can offer three different cleanroom configurations. Please let us know your required size:
A x 150 m² (3 chambers)
B x 320 m² (7 chambers) – 112 m² + 55 m² + 34 m² + 38 m² + 40 m² + 25 m²
C x (please specify)
Item 1) Cleanroom Block 1 approx. 150 m²
Inlet with the following technical specifications:
- Cleanroom Class ISO6
- Lighting: 300 lux
- All doors equipped with electric locks
Manufacturer and model: MGB
- Clear room height: 2,500 mm throughout
On-site extraction system: 500–2,000 m³/h
Inlet slot: 1,800 x 50 mm
Outlet 1: 3,700 x 50 mm
Outlet slot: 1,800 x 50 mm
2 double doors
1 maintenance door
• DIG Cell: Solvent extraction via industrial exhaust fan
Manufacturer: Ghrd, with external drive motor and frequency converter
Approx. 5 g/m² solvent applied to the panel
Exhaust duct outlets 2 m above the cell
Roof penetrations and sealing to be provided by the customer
Negative pressure monitoring included
2 double doors
• T Cell: Extraction via industrial exhaust fan
Chedpjw Dddzjfx Abtec
Manufacturer: Ghrd, with external drive motor and frequency converter
Exhaust air combined with that of the DIG cell
Negative pressure monitoring to prevent solvent leakage to exterior
2 double doors
Comprising:
- Approx. 175 m² tongue-and-groove panel walls, RAL 9002, smooth finish, with eccentric fasteners
- Multiple window elements integrated into the panel walls as per specification
6 doors with windows (double-leaf, clear opening 1,800 x 2,000 mm)
1 operating room door (single-leaf, clear opening 2,000 x 2,200 mm)
6 electric door locks as described
22 filter fan units (1,140 x 1,140 mm each), with F7 pre-filter, H14 main filter, EC speed-controllable motor
Air volume: 2,350 m³/h
Nominal power: 350 W
Sound power: approx. 55 dB(A)
Approx. 40 lighting units with cover (no LED)
Approx. 200 m² cleanroom ceiling, make: O – metal ceiling
1 set of suspension structure for the metal ceiling, including maintenance grid for service and filter replacement from above
1 exhaust fan with ductwork
1 switch cabinet section for control
Additional option:
Item 3) Additional Air Conditioning for DIG Room
To achieve the specified room temperature and humidity, an additional air conditioning unit is required:
- Target room temperature: +20°C ±2K
- Target humidity: 60% ±10%
- Control integrated into main control cabinet
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
We can offer three different cleanroom configurations. Please let us know your required size:
A x 150 m² (3 chambers)
B x 320 m² (7 chambers) – 112 m² + 55 m² + 34 m² + 38 m² + 40 m² + 25 m²
C x (please specify)
Item 1) Cleanroom Block 1 approx. 150 m²
Inlet with the following technical specifications:
- Cleanroom Class ISO6
- Lighting: 300 lux
- All doors equipped with electric locks
Manufacturer and model: MGB
- Clear room height: 2,500 mm throughout
On-site extraction system: 500–2,000 m³/h
Inlet slot: 1,800 x 50 mm
Outlet 1: 3,700 x 50 mm
Outlet slot: 1,800 x 50 mm
2 double doors
1 maintenance door
• DIG Cell: Solvent extraction via industrial exhaust fan
Manufacturer: Ghrd, with external drive motor and frequency converter
Approx. 5 g/m² solvent applied to the panel
Exhaust duct outlets 2 m above the cell
Roof penetrations and sealing to be provided by the customer
Negative pressure monitoring included
2 double doors
• T Cell: Extraction via industrial exhaust fan
Chedpjw Dddzjfx Abtec
Manufacturer: Ghrd, with external drive motor and frequency converter
Exhaust air combined with that of the DIG cell
Negative pressure monitoring to prevent solvent leakage to exterior
2 double doors
Comprising:
- Approx. 175 m² tongue-and-groove panel walls, RAL 9002, smooth finish, with eccentric fasteners
- Multiple window elements integrated into the panel walls as per specification
6 doors with windows (double-leaf, clear opening 1,800 x 2,000 mm)
1 operating room door (single-leaf, clear opening 2,000 x 2,200 mm)
6 electric door locks as described
22 filter fan units (1,140 x 1,140 mm each), with F7 pre-filter, H14 main filter, EC speed-controllable motor
Air volume: 2,350 m³/h
Nominal power: 350 W
Sound power: approx. 55 dB(A)
Approx. 40 lighting units with cover (no LED)
Approx. 200 m² cleanroom ceiling, make: O – metal ceiling
1 set of suspension structure for the metal ceiling, including maintenance grid for service and filter replacement from above
1 exhaust fan with ductwork
1 switch cabinet section for control
Additional option:
Item 3) Additional Air Conditioning for DIG Room
To achieve the specified room temperature and humidity, an additional air conditioning unit is required:
- Target room temperature: +20°C ±2K
- Target humidity: 60% ±10%
- Control integrated into main control cabinet
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.