Primus Engineering
Type: DST 350
This test setup was designed for performing IP protection tests for “dust” according to, for example, DIN 40050 Part 9 and DIN EN 60529.
The test setup is intended for testing technical components under the influence of dust and negative pressure within the limits specified in the technical data.
Operation / HMI
Control panel with screen and buttons
Manual controls
Pre-programmed test sequences
Integrated vacuum circuit with flow measurement
Technical data:
Total electrical power: Max. 5 KW
Connection voltage: 400V/50HZ 3-N/PE (16A EEC socket)
Dimensions: Width approx. 920 mm, Depth approx. 710 mm, Height approx. 1,770 mm
Test chamber dimensions: Width approx. 700 mm, Depth approx. 650 mm, Height approx. 770 mm
Volume approx. 350 l
Weight: approx. 200 kg
Vacuum: 0 to -100 mbar
Suction air flow: 0 to approx. 5 l/min
Operating climate range: Temperature: +12 °C to +30 °C
Humidity: 25 % rel. to 75 % rel., non-condensing
IP protection tests according to DIN 40050 Part 9 and DIN EN 60529 (VDE 0470 Part 1)
Dust test:
Dust-protected IP5X and IP5KX
Dust-tight IP6X and IP6KX
with and without vacuum
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
Ibsdpezgbtiefx Aqrec
We will be happy to answer any further questions you may have by telephone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Type: DST 350
This test setup was designed for performing IP protection tests for “dust” according to, for example, DIN 40050 Part 9 and DIN EN 60529.
The test setup is intended for testing technical components under the influence of dust and negative pressure within the limits specified in the technical data.
Operation / HMI
Control panel with screen and buttons
Manual controls
Pre-programmed test sequences
Integrated vacuum circuit with flow measurement
Technical data:
Total electrical power: Max. 5 KW
Connection voltage: 400V/50HZ 3-N/PE (16A EEC socket)
Dimensions: Width approx. 920 mm, Depth approx. 710 mm, Height approx. 1,770 mm
Test chamber dimensions: Width approx. 700 mm, Depth approx. 650 mm, Height approx. 770 mm
Volume approx. 350 l
Weight: approx. 200 kg
Vacuum: 0 to -100 mbar
Suction air flow: 0 to approx. 5 l/min
Operating climate range: Temperature: +12 °C to +30 °C
Humidity: 25 % rel. to 75 % rel., non-condensing
IP protection tests according to DIN 40050 Part 9 and DIN EN 60529 (VDE 0470 Part 1)
Dust test:
Dust-protected IP5X and IP5KX
Dust-tight IP6X and IP6KX
with and without vacuum
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
Ibsdpezgbtiefx Aqrec
We will be happy to answer any further questions you may have by telephone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp