Gönguhæf loftslagsklefi með rakastýringuRS-Simulatoren
KKM 110/45 -40°C bis +120°C
Gönguhæf loftslagsklefi með rakastýringu
RS-Simulatoren
KKM 110/45 -40°C bis +120°C
Ástand
Notað
Staðsetning
Borken 

Upplýsingar um vélina
- Heiti vélar:
- Gönguhæf loftslagsklefi með rakastýringu
- Framleiðandi:
- RS-Simulatoren
- Ástand:
- mjög gott (notað)
Verð og staðsetning
- Staðsetning:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A22271267
- Tilvísunarnúmer:
- 24675
- Uppfærsla:
- síðast þann 06.07.2026
Lýsing
RS Simulators
Type: KKM 110/45
Manufacturer: RS-Simulatoren, water-cooled
Climate chamber 110m³ incl. condenser
The KKM 110/45 type belongs to the TKM/KKM modular design of RS-Simulatoren,
meaning it is a climate chamber with a modular structure that is assembled on-site.
This design offers:
Modularity: Individual segments are pre-assembled and installed at the customer's location.
This makes retrofitting (more depth or additional modules) as well as later relocation straightforward.
Technical data climate chamber:
Manufacturer: RS-Simulatoren Prüf- und Messtechnik GmbH
Type: KKM 110/45
External dimensions: 6200 x 9400 x 3400 (W x D x H in mm) incl. technical attachments
Internal dimensions: 5900 x 7000 x 2960 (W x D x H in mm)
Chamber door (double-leaf) 3600 x 2930 (W x H in mm)
Personnel door (single-leaf) on side wall 1880 x 900 (H x W in mm)
Feedthroughs: 8 x Ø120mm (4x left & 4x right)
Windows: 1x (460 x 550mm) in the front chamber door, heated
1x (1260 x 1000mm) in the left side wall, heated
Temperature range: -40°C to +120°C
Time deviation: ± 0.8K – 1.5K according to DIN 50011 in an empty test chamber
Humidity range: 10% to 95%
Humidity tolerance: +/- 5.0%
Refrigerant: 2x R404A 52kg
2x R23 17kg
Temperature change rate:
Heating: 1.0 K/min
Cooling: 1.0 K/min
Cgjdpfx Acozizlds Uow
Max. surface load 500kg / m²
Electrical data:
Voltage: 3x400V/N/PE Current: 340A
Weight: approx. 2,000 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerants
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will gladly answer any further questions you may have on the phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Type: KKM 110/45
Manufacturer: RS-Simulatoren, water-cooled
Climate chamber 110m³ incl. condenser
The KKM 110/45 type belongs to the TKM/KKM modular design of RS-Simulatoren,
meaning it is a climate chamber with a modular structure that is assembled on-site.
This design offers:
Modularity: Individual segments are pre-assembled and installed at the customer's location.
This makes retrofitting (more depth or additional modules) as well as later relocation straightforward.
Technical data climate chamber:
Manufacturer: RS-Simulatoren Prüf- und Messtechnik GmbH
Type: KKM 110/45
External dimensions: 6200 x 9400 x 3400 (W x D x H in mm) incl. technical attachments
Internal dimensions: 5900 x 7000 x 2960 (W x D x H in mm)
Chamber door (double-leaf) 3600 x 2930 (W x H in mm)
Personnel door (single-leaf) on side wall 1880 x 900 (H x W in mm)
Feedthroughs: 8 x Ø120mm (4x left & 4x right)
Windows: 1x (460 x 550mm) in the front chamber door, heated
1x (1260 x 1000mm) in the left side wall, heated
Temperature range: -40°C to +120°C
Time deviation: ± 0.8K – 1.5K according to DIN 50011 in an empty test chamber
Humidity range: 10% to 95%
Humidity tolerance: +/- 5.0%
Refrigerant: 2x R404A 52kg
2x R23 17kg
Temperature change rate:
Heating: 1.0 K/min
Cooling: 1.0 K/min
Cgjdpfx Acozizlds Uow
Max. surface load 500kg / m²
Electrical data:
Voltage: 3x400V/N/PE Current: 340A
Weight: approx. 2,000 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerants
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will gladly answer any further questions you may have on the phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri