Loftslag hólfWEISS
WK1-1000/70
Loftslag hólf
WEISS
WK1-1000/70
Ástand
Notað
Staðsetning
Borken 

Myndir sýna
Sýna kort
Upplýsingar um vélina
Verð og staðsetning
- Staðsetning:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A15257365
- Tilvísunarnúmer:
- 24046
- Uppfærsla:
- síðast þann 14.02.2025
Lýsing
White
Type: WK1-1000/70
Weiss climatic test chamber water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered by simply touching the function icons on the
all control and operating commands by simply touching the function icons.
Feedthroughs
The test chamber is equipped with feed-throughs on the right and left side.
Measurement cables and test equipment can be routed into the test chamber through these.
Feed-throughs:
Ledpfxervx Eze Aa Toai
1 feed-through ∅ 125 mm installed on the right
1 feed-through ∅ 50 mm installed on the left
Volume 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, 1980 mm
Data for temperature tests:
Minimum temperature -70 °C
Maximum temperature +180 °C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 2 K
Temperature change rate, heating 4 K/min
Temperature change rate, cooling 2.5 K/min
Max. heat compensation 2750 W
Data for climate tests:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ± 1 K
Humidity deviation, temporal ± 1 to ± 3% r.h.
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A Nominal power 19.8 kW
Refrigerant: R-452A/ R23
Weight approx. 910kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Type: WK1-1000/70
Weiss climatic test chamber water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered by simply touching the function icons on the
all control and operating commands by simply touching the function icons.
Feedthroughs
The test chamber is equipped with feed-throughs on the right and left side.
Measurement cables and test equipment can be routed into the test chamber through these.
Feed-throughs:
Ledpfxervx Eze Aa Toai
1 feed-through ∅ 125 mm installed on the right
1 feed-through ∅ 50 mm installed on the left
Volume 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, 1980 mm
Data for temperature tests:
Minimum temperature -70 °C
Maximum temperature +180 °C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 2 K
Temperature change rate, heating 4 K/min
Temperature change rate, cooling 2.5 K/min
Max. heat compensation 2750 W
Data for climate tests:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ± 1 K
Humidity deviation, temporal ± 1 to ± 3% r.h.
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A Nominal power 19.8 kW
Refrigerant: R-452A/ R23
Weight approx. 910kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2012
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
lítil auglýsing
Þýskaland
2.280 km
Tunnel gerilsneyðari
KronesLC 23.6-523-31
KronesLC 23.6-523-31
lítil auglýsing
Viechtach
2.569 km
Rafmagns CNC þrýstibremsa - 40 tonn
DURMAAD-ES 1240
DURMAAD-ES 1240
lítil auglýsing
Terrassa
2.928 km
Tómarúmdæla með snúningsvél
Oerlikon LeyboldSV 300
Oerlikon LeyboldSV 300
lítil auglýsing
Birmingham
1.695 km
Hnoðunarvél
Haeger412
Haeger412
lítil auglýsing
Borken
2.072 km
Loftslagsskápur með rakastigi 34 lítrar
WeissWKL 34/60 -60°C bis 150°C
WeissWKL 34/60 -60°C bis 150°C
lítil auglýsing
Zuchwil
2.536 km
Retort hitameðferðarofni
MUT360/400-1150
MUT360/400-1150
lítil auglýsing
Þýskaland
2.280 km
Hluti fellibekkur 1,25m, beygjuvél
Prod-Masz Segmentabkantbank Abkantbank24Abkantbank 1,25m/1.5 3 fach segmentiert
Prod-Masz Segmentabkantbank Abkantbank24Abkantbank 1,25m/1.5 3 fach segmentiert
lítil auglýsing
Borken
2.072 km
Loftslag hólf
VötschVC³ 4060
VötschVC³ 4060
lítil auglýsing
Işıktepe OSB
4.088 km
Ýttu á Brake
BaykalBAYKAL CNC APHS HYBRID PRESS BRAKE
BaykalBAYKAL CNC APHS HYBRID PRESS BRAKE
lítil auglýsing
Berlin
2.286 km
Stafræn prentvél
HPIndigo WS 4500
HPIndigo WS 4500
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp