Klimaskápur með raka, 34 lítrarWeiss
WKL 34/40 -40...+150°C
Klimaskápur með raka, 34 lítrar
Weiss
WKL 34/40 -40...+150°C
Ástand
Notað
Staðsetning
Borken 

Myndir sýna
Sýna kort
Upplýsingar um vélina
Verð og staðsetning
- Staðsetning:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A20492700
- Tilvísunarnúmer:
- 24870
- Uppfærsla:
- síðast þann 10.11.2025
Lýsing
Weiss
Model: WKL 34/40
Kdedpfx Asxvpp Recxow
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber volume: 34 litres
Feedthroughs included as standard:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Specifications for temperature testing:
Temperature range: -40 to +150 °C
Temperature deviations at steady state (according to IEC 60068-3-5):
Temporal fluctuation in centre of usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial deviation (temperature gradient): 2 to 4 K
Rate of temperature change (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Max. heat compensation: 800 W
Specifications for climate testing:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % RH
Temperature and humidity fluctuations (at steady state, according to IEC 60068-3-5):
Temperature fluctuation (temporal, centre of usable space): ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K (temperature gradient): 1 to 3 K
Humidity fluctuation (temporal, centre of usable space): ± 3 to ± 5 % RH
Operating data:
Test chamber lighting: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Protection (on site): 16A slow-blow
Heat output (air-cooled test chambers):
Max. heat emission to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important notice:
“The table shown in the photos is not included in the sale.”
For your safety as a buyer, please note the following:
The following procedures are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data and specifications subject to change and error!)
If you have any further questions, we will gladly answer them by phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Model: WKL 34/40
Kdedpfx Asxvpp Recxow
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber volume: 34 litres
Feedthroughs included as standard:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Specifications for temperature testing:
Temperature range: -40 to +150 °C
Temperature deviations at steady state (according to IEC 60068-3-5):
Temporal fluctuation in centre of usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial deviation (temperature gradient): 2 to 4 K
Rate of temperature change (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Max. heat compensation: 800 W
Specifications for climate testing:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % RH
Temperature and humidity fluctuations (at steady state, according to IEC 60068-3-5):
Temperature fluctuation (temporal, centre of usable space): ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K (temperature gradient): 1 to 3 K
Humidity fluctuation (temporal, centre of usable space): ± 3 to ± 5 % RH
Operating data:
Test chamber lighting: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Protection (on site): 16A slow-blow
Heat output (air-cooled test chambers):
Max. heat emission to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important notice:
“The table shown in the photos is not included in the sale.”
For your safety as a buyer, please note the following:
The following procedures are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data and specifications subject to change and error!)
If you have any further questions, we will gladly answer them by phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2012
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
lítil auglýsing
Kölleda
2.308 km
Neistalitrófsmælir
SPECTROLAVMC05A SPECTROLAB
SPECTROLAVMC05A SPECTROLAB
lítil auglýsing
Borken
2.072 km
Rafeindasmásjá
ZeissEVO 50 inkl. EDS Ultim Max 100
ZeissEVO 50 inkl. EDS Ultim Max 100
lítil auglýsing
Mainz
2.299 km
Rasterrafeindasmásjá (REM)
ZeissXB 350
ZeissXB 350
lítil auglýsing
Borken
2.072 km
Loftslag hólf
CTSC-40/200
CTSC-40/200
lítil auglýsing
Borken
2.072 km
Hitaprófunarskápur
Heraeus VötschHT 7010 -70°C bis +180°C
Heraeus VötschHT 7010 -70°C bis +180°C
lítil auglýsing
Borken
2.072 km
Loftslagsskápur til skiptis
BinderMKF 720 E1 / E1.1
BinderMKF 720 E1 / E1.1
lítil auglýsing
Borken
2.072 km
Hitaskápur
WEISSWT3- 180/40
WEISSWT3- 180/40
lítil auglýsing
Köln
2.159 km
Hreint loft vinnubekkur
HeraguardHPH 15
HeraguardHPH 15
lítil auglýsing
Tönisvorst
2.103 km
Mælissúla (27911)
Höhe 500 mmDurchmesser 120 mm
Höhe 500 mmDurchmesser 120 mm
lítil auglýsing
Þýskaland
7.393 km
Síukerfi - osmósakerfi
Thermo Fisher ScientificECO 300
Thermo Fisher ScientificECO 300
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp

































































































