LosunarprófunarhólfWEISS
WT 5,1'/ + 18-45
Losunarprófunarhólf
WEISS
WT 5,1'/ + 18-45
föst verð aukaskattur bætist við
130.000 EUR
Ástand
Notað
Staðsetning
Borken 

Upplýsingar um vélina
Verð og staðsetning
föst verð aukaskattur bætist við
130.000 EUR
- Staðsetning:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A22148392
- Tilvísunarnúmer:
- 23531
- Uppfærsla:
- síðast þann 18.06.2026
Lýsing
Weiss
Here, we offer a Weiss emission test chamber.
Mini - SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Iaodszd Slkspfx Adhsu
Duct connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation; scope of supply: connecting flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3-phase + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Weight: approx. 2500 kg
Type: WT 5.1'/ + 18-45
Condition: used
Sale from our location
Scope of supply: (Only the Weiss emission test chamber WT 5.1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Here, we offer a Weiss emission test chamber.
Mini - SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Iaodszd Slkspfx Adhsu
Duct connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation; scope of supply: connecting flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3-phase + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Weight: approx. 2500 kg
Type: WT 5.1'/ + 18-45
Condition: used
Sale from our location
Scope of supply: (Only the Weiss emission test chamber WT 5.1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp