Hitaprófunarskápur 600 lítrarWeiss
WT3-600/40 -42°C bis +180°C
Hitaprófunarskápur 600 lítrar
Weiss
WT3-600/40 -42°C bis +180°C
Ástand
Notað
Staðsetning
Borken 

Myndir sýna
Sýna kort
Upplýsingar um vélina
Verð og staðsetning
- Staðsetning:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A21151962
- Tilvísunarnúmer:
- 23955
- Uppfærsla:
- síðast þann 03.02.2026
Lýsing
We are offering a Weiss temperature test chamber for sale.
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Bcedsyguh Iopfx Aglou
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Bcedsyguh Iopfx Aglou
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2012
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
Lítil auglýsing
Borken
2.072 km
Hitaprófunarskápur 600 lítrar
WeissWT3-600/40 -42°C bis +180°C
WeissWT3-600/40 -42°C bis +180°C
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp