FlúrljómunarlitrófsmælirAgilent
Eclipse
Flúrljómunarlitrófsmælir
Agilent
Eclipse
framleiðsluár
2017
Ástand
Notað
Staðsetning
Bretland 

Myndir sýna
Sýna kort
Upplýsingar um vélina
- Heiti vélar:
- Flúrljómunarlitrófsmælir
- framleiðandi:
- Agilent
- Gerð:
- Eclipse
- framleiðsluár:
- 2017
- Ástand:
- tilbúinn til notkunar (notaður)
Verð og staðsetning
- Staðsetning:
- Location:Duxford, United Kingdom
Hringdu
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A18143956
- Tilvísunarnúmer:
- 412977
- uppfærsla:
- síðast þann 25.02.2025
Lýsing
Condition Used
Stock Number 412977
This listing is for a Agilent Eclipse Fluorescence Spectrometer.
The unit is in full working condition and is ready for immediate release.
Itodpfsvl A Ayex Afwsn
Supplied with cables, software disk, License key,spare diffuser and Neutral density attenuator.
The Agilent Cary Eclipse fluorescence spectrometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
Type:Benchtop fluorescence spectrometer
Control Software :Cary WinFLR
Light Source:Xenon flash lamp (80 Hz) with 10-year warranty on new instruments
Maximum Scanning Speed :24,000 nm/min
Modes of Operation:Fluorescence,Phosphorescence,Chemiluminescence,Biolumi nescence,Time resolved phosphorescence.
Power Requirements:100-240 VAC, 50/60 Hz
Spectral Bandwidth Emission: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Excitation: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Wavelength Accuracy:± 1.5 nm
Wavelength Range:Operational emission: 200 - 900 nm
Operational excitation: 200 - 900 nm
Depth:644 mm
Height:271 mm
Weight:30 kg
Width:608 mm
Stock Number 412977
This listing is for a Agilent Eclipse Fluorescence Spectrometer.
The unit is in full working condition and is ready for immediate release.
Itodpfsvl A Ayex Afwsn
Supplied with cables, software disk, License key,spare diffuser and Neutral density attenuator.
The Agilent Cary Eclipse fluorescence spectrometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
Type:Benchtop fluorescence spectrometer
Control Software :Cary WinFLR
Light Source:Xenon flash lamp (80 Hz) with 10-year warranty on new instruments
Maximum Scanning Speed :24,000 nm/min
Modes of Operation:Fluorescence,Phosphorescence,Chemiluminescence,Biolumi nescence,Time resolved phosphorescence.
Power Requirements:100-240 VAC, 50/60 Hz
Spectral Bandwidth Emission: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Excitation: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Wavelength Accuracy:± 1.5 nm
Wavelength Range:Operational emission: 200 - 900 nm
Operational excitation: 200 - 900 nm
Depth:644 mm
Height:271 mm
Weight:30 kg
Width:608 mm
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Skráð frá: 2019
Senda fyrirspurn
Sími & Fax
+44 20 38... auglýsingar
Þessar auglýsingar gætu einnig vakið áhuga þinn.
lítil auglýsing

2.072 km
Litrófsmælir ónotaður í upprunalegum umbúðum
Agilent TechnologiesCary Eclipse G9800A
Agilent TechnologiesCary Eclipse G9800A
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp