Hitaklefi 2000 lítrarCTS
T-40/2000 -40°C bis +180°C
Hitaklefi 2000 lítrar
CTS
T-40/2000 -40°C bis +180°C
Ástand
Notað
Staðsetning
Borken 

Myndir sýna
Sýna kort
Upplýsingar um vélina
Verð og staðsetning
- Staðsetning:
- Einsteinstraße 8a, 46325 Borken, DE
Hringdu
Vélasala

Hefur þú þegar auglýst notaða vélina þína?
Seldu í gegnum Machineseeker án þóknunar.
Meira um sölu á vélum
Meira um sölu á vélum
Tilboðsupplýsingar
- Auglýsingarauðkenni:
- A17202157
- Tilvísunarnúmer:
- 24329
- uppfærsla:
- síðast þann 15.11.2024
Lýsing
CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Dwodpfxeup T Uqo Aczjc
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Dwodpfxeup T Uqo Aczjc
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Þessi auglýsing var sjálfvirkt þýdd. Villa í þýðingu gæti verið til staðar.
Bjóðandi
Athugasemd: Skráðu þig ókeypis eða skráðu þig inn, til að fá aðgang að öllum upplýsingum.
Senda fyrirspurn
Sími & Fax
+49 2861 ... auglýsingar
Auglýsingunni þinni hefur verið eytt með góðum árangri
Villa kom upp